posted on 2023-09-25, 06:50authored byKenta Tomyta, Hideki Ohira, Kentaro Katahira
In synchronization tapping tasks, tapping onset often precedes metronome one by a few tens of milliseconds, which is known as negative mean asynchrony. However, the mechanism by which negative mean asynchrony occurs remains incompletely understood. This study hypothesized that one of the mechanisms was the asymmetric error correction process for asynchrony. We examined this hypothesis using a generalized linear mixed model. The results suggested that the error correction rate for the positive asynchrony was larger than that for the negative asynchrony. This finding may contribute to improving mathematical models of the synchronization tapping task.